Development time
Ilford Delta 3200 in Microphen
9:00 at 20°C (68°F), stock dilution, box speed.
Start timer · 9:00- Time
- 9:00
- Dilution
- Stock
- Temperature
- 20°C
- Box speed
- ISO 3200
All 8 times
| Dilution | EI | Time | Temp | Agitation | Evidence | Timer |
|---|---|---|---|---|---|---|
| Stock | 3200 | 9:00 | 20°C / 68°F | Standard | ManufacturerChecked Jan 2026 | Start timer |
| 1+1 | 3200 | 12:30Not yet verified | 20°C / 68°F | Standard | Community consensusChecked Jan 2026 | Start timer |
| Stock | 400−3 stops | 6:00 | 20°C / 68°F | Standard | ManufacturerChecked Oct 2026 | Start timer |
| Stock | 800−2 stops | 7:00 | 20°C / 68°F | Standard | ManufacturerChecked Oct 2026 | Start timer |
| Stock | 1600−1 stop | 8:00 | 20°C / 68°F | Standard | ManufacturerChecked Oct 2026 | Start timer |
| Stock | 6400+1 stop | 12:00 | 20°C / 68°F | Standard | ManufacturerChecked Oct 2026 | Start timer |
| Stock | 12500+2 stops | 16:30 | 20°C / 68°F | Standard | ManufacturerChecked Oct 2026 | Start timer |
| Stock | 25000+3 stops | 17:30 | 20°C / 68°F | Standard | ManufacturerChecked Oct 2026 | Start timer |
EI is the speed the film was rated at when shooting. Evidence says where each time comes from: the manufacturer’s own data, a named test, a compilation or several agreeing reports (community consensus), or one person’s report. Times marked “not yet verified” come from secondary sources and haven’t been checked against a manufacturer datasheet. Where sources give different times, every one is listed and marked “sources differ”.
Other temperatures
| 18°C64°F | 19°C66°F | 20°C68°F | 21°C70°F | 22°C72°F | 23°C73°F | 24°C75°F |
|---|---|---|---|---|---|---|
| 11:15 | 10:05 | 9:00 | 8:06 | 7:12 | 6:29 | 5:51 |
Calculated from the 20°C (68°F) time using Ilford’s temperature compensation factors, not taken from a datasheet. Most B&W developers behave well between 18–24°C (64–75°F).
Mixing
| Dilution | 300 ml (10.1 fl oz) (one 35mm roll) | 500 ml (16.9 fl oz) (one 120 roll) |
|---|---|---|
| Stock | Use as mixed, undiluted | Use as mixed, undiluted |
| 1+1 | 150 ml developer + 150 ml water | 250 ml developer + 250 ml water |
How they work together
- Microphen
- Fine grain, moderate acutance, normal contrast. Fine grain with an effective speed increase.
- Ilford Delta 3200
- Ultra-high-speed film with a visible grain structure, recommended by Ilford at EI 3200 (measured ISO 1000/31) and given extended development; low native contrast allows heavy pushing.
- Notes on this pairing
- High speed developer recommended for Delta 3200.
- Speed-enhancing developer with fine grain retention. Unverified: no film or developer maker publishes this time; Massive Dev Chart (community chart) cache holds no times. Ilford lists Delta 3200 in Microphen stock only.
- Ilford recommended developer for this film.
Delta 3200 in other developers
Other films in Microphen
Ilford HP5 Plus
6:30
Stock · EI 400 · 20°C · 7 variants
Ilford Delta 400
6:30
Stock · EI 400 · 20°C · 12 variants
Ilford FP4 Plus
8:00
Stock · EI 125 · 20°C · 7 variants
Foma Bohemia Fomapan 400 Action
8:00
Stock · EI 400 · 20°C · 4 variants
Harman Technology Kentmere Pan 400
8:00
Stock · EI 400 · 20°C · 4 variants
Harman Technology Kentmere Pan 100
8:30
Stock · EI 100 · 20°C · 5 variants
Ilford Ilford Delta 100
6:30
Stock · EI 100 · 20°C · 7 variants
Ilford Pan F Plus 50
4:30
Stock · EI 50 · 20°C · 8 variants