Formula
Traditional cyanotype, solution B (Mike Ware)
- Use
- Sensitiser
- Ingredients
- 1
- Water to make
- 100 mL (distilled)
Handle chemistry safely
Wear gloves and eye protection, work with good ventilation, and read the supplier’s safety data sheet before use. Hazard information here is a summary, not a replacement for it. Dispose of all photographic chemistry correctly, in line with local laws and your local authority’s guidance. Never mix waste solutions, and check the supplier’s safety data sheet before disposing of anything.
Ingredients
| Chemical | Amount |
|---|---|
| Potassium ferricyanide | 10 g |
| Water to make | 100 mL (distilled) |
Notes
Dissolve the potassium ferricyanide in about 80 mL of distilled water at room temperature, then add water to make 100 mL. The strength need not be exact. Keep it in a brown bottle in the dark. Mix it with an equal volume of solution A shortly before coating.
Amounts as published. Chemical forms (anhydrous, monohydrate and so on) change the weights, so match the form listed.