Skip to main content

Development time

Ilford Ortho Plus in Perceptol

13:00 at 20°C (68°F), stock dilution, box speed.

Start timer · 13:00
Time
13:00
Standard
Dilution
Stock
Temperature
20°C
68°F
Box speed
ISO 80
B&W

Development time

DilutionEITimeTempAgitationEvidenceTimer
Stock8013:0020°C / 68°FStandardManufacturerChecked Jan 2026Start timer

EI is the speed the film was rated at when shooting. Evidence says where each time comes from: the manufacturer’s own data, a named test, a compilation or several agreeing reports (community consensus), or one person’s report. Times marked “not yet verified” come from secondary sources and haven’t been checked against a manufacturer datasheet. Where sources give different times, every one is listed and marked “sources differ”.

Other temperatures

18°C64°F19°C66°F20°C68°F21°C70°F22°C72°F23°C73°F24°C75°F
16:1514:3413:0011:4210:249:228:27

Calculated from the 20°C (68°F) time using Ilford’s temperature compensation factors, not taken from a datasheet. Most B&W developers behave well between 18–24°C (64–75°F).

Mixing

Dilution300 ml (10.1 fl oz) (one 35mm roll)500 ml (16.9 fl oz) (one 120 roll)
StockUse as mixed, undilutedUse as mixed, undiluted

How they work together

Perceptol
Moderate acutance, normal contrast. Extremely fine grain, for when a loss of film speed is acceptable.
Ilford Ortho Plus
Orthochromatic film (ISO 80 daylight, 40 tungsten) sensitive to blue and green only, so it can be handled under red safelight and developed by inspection; reds and oranges render dark. 35mm and 120 added in November 2019.
Notes on this pairing
  • Pictorial contrast (Gbar 0.62). Ilford ORTHO Plus technical information (Oct 2019), 20°C: 13:00.

Ortho Plus in other developers

Other films in Perceptol