Development time
Ilford Ortho Plus in Perceptol
13:00 at 20°C (68°F), stock dilution, box speed.
Start timer · 13:00- Time
- 13:00
- Dilution
- Stock
- Temperature
- 20°C
- Box speed
- ISO 80
Development time
| Dilution | EI | Time | Temp | Agitation | Evidence | Timer |
|---|---|---|---|---|---|---|
| Stock | 80 | 13:00 | 20°C / 68°F | Standard | ManufacturerChecked Jan 2026 | Start timer |
EI is the speed the film was rated at when shooting. Evidence says where each time comes from: the manufacturer’s own data, a named test, a compilation or several agreeing reports (community consensus), or one person’s report. Times marked “not yet verified” come from secondary sources and haven’t been checked against a manufacturer datasheet. Where sources give different times, every one is listed and marked “sources differ”.
Other temperatures
| 18°C64°F | 19°C66°F | 20°C68°F | 21°C70°F | 22°C72°F | 23°C73°F | 24°C75°F |
|---|---|---|---|---|---|---|
| 16:15 | 14:34 | 13:00 | 11:42 | 10:24 | 9:22 | 8:27 |
Calculated from the 20°C (68°F) time using Ilford’s temperature compensation factors, not taken from a datasheet. Most B&W developers behave well between 18–24°C (64–75°F).
Mixing
| Dilution | 300 ml (10.1 fl oz) (one 35mm roll) | 500 ml (16.9 fl oz) (one 120 roll) |
|---|---|---|
| Stock | Use as mixed, undiluted | Use as mixed, undiluted |
How they work together
- Perceptol
- Moderate acutance, normal contrast. Extremely fine grain, for when a loss of film speed is acceptable.
- Ilford Ortho Plus
- Orthochromatic film (ISO 80 daylight, 40 tungsten) sensitive to blue and green only, so it can be handled under red safelight and developed by inspection; reds and oranges render dark. 35mm and 120 added in November 2019.
- Notes on this pairing
- Pictorial contrast (Gbar 0.62). Ilford ORTHO Plus technical information (Oct 2019), 20°C: 13:00.
Ortho Plus in other developers
D-76
8:00
Stock · EI 80 · 20°C · 2 variants
ID-11
8:00
Stock · EI 80 · 20°C · 3 variants
Ilfosol 3
5:00
1+9 · EI 80 · 20°C · 2 variants
Ilfotec DD-X
10:30
1+4 · EI 80 · 20°C
Ilfotec HC
4:00
1+15 · EI 80 · 20°C · 2 variants
Ilfotec LC29
4:00
1+9 · EI 80 · 20°C · 2 variants
Microphen
9:00
Stock · EI 80 · 20°C · 3 variants
Other films in Perceptol
Ilford HP5 Plus
13:00
Stock · EI 250 · 20°C · 6 variants
Ilford Delta 3200
18:00
Stock · EI 3200 · 20°C · 4 variants
Ilford Delta 400
10:00
Stock · EI 200 · 20°C · 5 variants
Ilford FP4 Plus
12:00
Stock · EI 125 · 20°C · 7 variants
Foma Bohemia Fomapan 400 Action
9:00
Stock · EI 400 · 20°C · 2 variants
Harman Technology Kentmere Pan 400
23:00
1+1 · EI 320 · 20°C
Harman Technology Kentmere Pan 100
12:30
Stock · EI 100 · 20°C · 4 variants
Ilford Ilford Delta 100
15:00
Stock · EI 100 · 20°C · 7 variants