Development time
Kodak T-Max P3200 in XTOL
13:30 at 20°C (68°F), stock dilution, box speed.
Start timer · 13:30- Time
- 13:30
- Dilution
- Stock
- Temperature
- 20°C
- Box speed
- ISO 3200
All 16 times
| Dilution | EI | Time | Temp | Agitation | Evidence | Timer |
|---|---|---|---|---|---|---|
| Stock | 3200 | 13:30 | 20°C / 68°F | Standard | ManufacturerChecked Jan 2026 | Start timer |
| 1+1 | 3200 | 18:30 | 20°C / 68°F | Standard | ManufacturerChecked Jan 2026 | Start timer |
| Stock | 400−3 stops | 9:30 | 20°C / 68°F | Standard | ManufacturerChecked Oct 2026 | Start timer |
| Stock | 800−2 stops | 10:30 | 20°C / 68°F | Standard | ManufacturerChecked Oct 2026 | Start timer |
| Stock | 1600−1 stop | 11:30 | 20°C / 68°F | Standard | ManufacturerChecked Oct 2026 | Start timer |
| Stock | 3200 | 13:30 | 20°C / 68°F | Standard | ManufacturerChecked Oct 2026 | Start timer |
| Stock | 6400+1 stop | 15:15 | 20°C / 68°F | Standard | ManufacturerChecked Oct 2026 | Start timer |
| Stock | 12500+2 stops | 17:15 | 20°C / 68°F | Standard | ManufacturerChecked Oct 2026 | Start timer |
| Stock | 25000+3 stops | 19:00 | 20°C / 68°F | Standard | ManufacturerChecked Oct 2026 | Start timer |
| 1+1 | 400−3 stops | 12:30 | 20°C / 68°F | Standard | ManufacturerChecked Oct 2026 | Start timer |
| 1+1 | 800−2 stops | 14:00 | 20°C / 68°F | Standard | ManufacturerChecked Oct 2026 | Start timer |
| 1+1 | 1600−1 stop | 16:00 | 20°C / 68°F | Standard | ManufacturerChecked Oct 2026 | Start timer |
| 1+1 | 3200 | 18:30 | 20°C / 68°F | Standard | ManufacturerChecked Oct 2026 | Start timer |
| 1+1 | 6400+1 stop | 20:30 | 20°C / 68°F | Standard | ManufacturerChecked Oct 2026 | Start timer |
| 1+1 | 12500+2 stops | 22:30 | 20°C / 68°F | Standard | ManufacturerChecked Oct 2026 | Start timer |
| 1+1 | 25000+3 stops | 25:00 | 20°C / 68°F | Standard | ManufacturerChecked Oct 2026 | Start timer |
EI is the speed the film was rated at when shooting. Evidence says where each time comes from: the manufacturer’s own data, a named test, a compilation or several agreeing reports (community consensus), or one person’s report. Times marked “not yet verified” come from secondary sources and haven’t been checked against a manufacturer datasheet. Where sources give different times, every one is listed and marked “sources differ”.
Other temperatures
| 18°C64°F | 19°C66°F | 20°C68°F | 21°C70°F | 22°C72°F | 23°C73°F | 24°C75°F |
|---|---|---|---|---|---|---|
| 16:53 | 15:07 | 13:30 | 12:09 | 10:48 | 9:43 | 8:47 |
Calculated from the 20°C (68°F) time using Ilford’s temperature compensation factors, not taken from a datasheet. Most B&W developers behave well between 18–24°C (64–75°F).
Mixing
| Dilution | 300 ml (10.1 fl oz) (one 35mm roll) | 500 ml (16.9 fl oz) (one 120 roll) |
|---|---|---|
| Stock | Use as mixed, undiluted | Use as mixed, undiluted |
| 1+1 | 150 ml developer + 150 ml water | 250 ml developer + 250 ml water |
How they work together
- XTOL
- Fine grain, high acutance, full film speed, normal contrast. Excellent shadow detail with wide latitude.
- Kodak T-Max P3200
- Multi-speed continuous-tone film designed for push processing to EI 3200-6400. Well-suited for low-light and action photography.
- Notes on this pairing
- EI 3200. Kodak J-109 XTOL sheet, T-Max P3200 small tank stock at 68°F: 13½ min.
- CORRECTED from 960s. Kodak J-109 Table 1, T-Max P3200 EI 3200, XTOL 1:1 small tank 68F: 18½ min. Film maker publishes no XTOL time in the data sheets read.
- Small tank, agitation every 30 s (F-4001, Apr 2019).
T-Max P3200 in other developers
Other films in XTOL
Kodak Tri-X 400
7:00
Stock · EI 400 · 20°C · 18 variants
Kodak T-Max 400
6:30
Stock · EI 400 · 20°C · 17 variants
Ilford HP5 Plus
8:00
Stock · EI 400 · 20°C · 6 variants
Ilford Delta 400
7:30
Stock · EI 400 · 20°C · 11 variants
Ilford FP4 Plus
8:30
Stock · EI 125 · 20°C · 2 variants
Ilford Ilford Delta 100
7:30
Stock · EI 100 · 20°C · 3 variants
Kodak T-Max 100
7:30
Stock · EI 100 · 20°C · 22 variants
Kodak Double-X 5222
7:00
Stock · EI 250 · 20°C · 2 variants